Product Directory / 2026

Product Center

Full-scenario solutions covering high-voltage high-power loads, marine loads, portable & wall-mounted loads, rack-mounted air/liquid-cooled loads, on-line genset testing and anti-islanding / weak-grid test fixtures.

20 PRODUCT SYSTEMS · R&D / EOL / SCADA
01

In-house RLC load banks covering AC 400V–13.8kV up to 10,000kW for performance and steady-state aging testing of gensets, UPS, PV inverters and storage PCS.

AC 400V–13.8kV0–10,000kWRack / Wall / ContainerRemote control
Learn more
02

CMA / CNAS accredited test center paired with on-line genset test systems — full-flow testing from R&D verification to EOL mass production.

CMA / CNASR&D verificationType approvalOn-site engineering
Learn more
03

Containerised resistive-inductive load bank that simulates the marine navigation load for genset stability and shore-power compatibility testing.

AC 400/440/690V0–4500kW0–3375kVar
Learn more
04

High-voltage resistive and capacitive load bank for testing, verification and maintenance of standby diesel gensets in data centres, both on site and at factory acceptance.

AC 10.5kV0–3000kW0–1450kVar
Learn more
05

Light, easy to operate and highly adaptable, for rapid on-site performance testing of gensets, UPS systems, inverters and switching power supplies, with parallel operation of multiple units.

AC 115–690V0–200kWParallel operation
Learn more
06

Provides on-board load testing for power generation and supply equipment on special vehicles such as communication, power-supply and emergency repair vehicles, in a compact reinforced design.

AC 115–690V / DC 270–800V0–100kWVehicle-grade reinforced build
Learn more
07

Forced air-cooled load device compatible with standard 19-inch cabinets, from 2U to 6U, for power ageing verification in data centres, communication rooms and laboratories.

19-inch cabinet integration1–10kW per 4U chassisStepless power adjustment
Learn more
08

High power-density liquid cooled load bank with ≤40dB noise, solving the heat-dissipation and noise limits of air-cooled loads in the high-power segment — built for indoor high-density deployment in data centres and AI computing halls.

Liquid cooling10–100kW per unitNoise ≤40dB
Learn more
09

Test equipment balancing large load capacity with mobility: a multi-mode mobile structure and reinforced frame for complex road conditions, deployed quickly with no fixed installation.

AC 115–690V / DC 270–800V0–1000kWRapid deployment
Learn more
10

Computer-based test system with a PLC control core and high-speed data acquisition for steady-state, transient, continuous-operation and harmonic testing of generator sets.

AC 0–15000V0–100000kWGB/T 2820 · ISO 8528
Learn more
11

Uses precision RLC loads to simulate islanding after grid failure, verifying that grid-tied inverters and storage converters detect islanding and disconnect reliably.

AC 0–1000V0–4000kWGrid-connection permission testing
Learn more
12

Simulates weak-grid conditions such as high network impedance, voltage/frequency fluctuation and three-phase imbalance to verify the grid adaptability of inverters and converters.

Adjustable SCR 1.0–10AC 0–1000V0–2000kW
Learn more
13

One AI-powered software suite with three test models — Automation for engineering test, Production for the line, SCADA for live plant control. Generate test programs in natural language and log 1000 channels at 1 kHz.

AI test program generationAutomation / Production / SCADA1000 channels @ 1 kHzSix modules
Learn more
14

Three compact Linux-based real-time controllers, entry-level to high performance, with control cycles down to 100 µs, built-in EtherCAT master, up to 16 CAN FD channels and one-click model deployment.

100 µs control cycleEtherCAT masterUp to 16 CAN FDOne-click model deploy
Learn more
15

Every testbed on one web dashboard — book benches, watch live status and collect results centrally. Built for Landi benches, open to the rest of your lab.

Bench bookingLive status boardCentral resultsAny browser
Learn more
16

One chassis, any measurement — 8 pluggable slots, auto-detected modules, installable software packages and hardware-timed synchronous sampling.

8 pluggable slotsAuto-detected modulesHardware-timed syncInstallable packages
Learn more
17

Comprehensive performance and endurance testing for joint modules, dexterous hands, ball screws, arms and legs.

NVHTorque / EfficiencyLife & AgingMulti-axis Sync
Learn more
18

EOL and R&D reducer testing for tier-1 customers such as ZF, covering precision, transmission efficiency and life.

BacklashEfficiencyStiffness CurveEOL
Learn more
19

A domestic leader in high-speed motor testing — including a 33,000 RPM dynamometer delivered for aerospace and NEV programs.

Up to 33,000 RPMTemp / Efficiency MAPNVHCooling Loop
Learn more
20

R&D and EOL benches for 3-in-1 electric drive and 2WD three-axis high-speed reducers, in mass production at many OEMs.

3-in-1 EOLMulti-speedFull-pack NVHRegen
Learn more